Results of Raw Water Quality Test at Condong Catur, Yogyakarta Special Region

Authors

  • Bambang Wisaksono Universitas Pembangunan Nasional Veteran Yogyakarta
  • Hari Dwi Wahyudi Universitas Pembangunan Nasional Veteran Yogyakarta
  • Syarifah Aini Universitas Pembangunan Nasional Veteran Yogyakarta
  • Heru Suharyadi Universitas Pembangunan Nasional Veteran Yogyakarta
  • Ilham Firmansyah Widya Dharma University

DOI:

https://doi.org/10.31098/ebs.v1i1.70

Keywords:

drill well, raw water, quality test

Abstract

The existing phenomenon is that groundwater in the UPN Veteran Yogyakarta integrated campus complex smells and has a reddish-brown color, and when the water is used for bathing, the skin becomes dry. Based on this phenomenon, it is assumed that the groundwater contains quite high levels of iron (Fe) and Manganese (Mn). The purpose of this research is to determine the quality of bore well water and determine the method of processing the well water so that it can be used as clean water that meets the requirements of Permenkes Number: 492/Menkes/Per/IV/2010 Water quality is a qualitative condition of a water sample taken from the source which is measured and/or tested based on certain parameters and certain methods based on predetermined test standards and is in effect at the time of the test. According to the standards stipulated in the Regulation of the Minister of Health of the Republic of Indonesia Number: 492/Menkes/Per/IV/2010 concerning Water Quality Control and Requirements, water quality testing parameters are generally grouped into 3 (three) parameters, namely: physical parameters, chemistry, and biology. In the laboratory tests carried out for samples of raw water from drilled well water sources at the UPN Veteran Yogyakarta Integrated Campus, the test parameters are taken are Physical parameters, including examination of odor, turbidity, taste, color, amount of dissolved solids (TDS); and Chemical Parameters, including examining pH, iron, fluoride, hardness, manganese, nitrate, nitrite. The results showed that the well water in the integrated campus complex area of UPN Veteran Yogyakarta has water quality parameters with levels of TDS, temperature, taste, odor, pH, fluoride, hardness, and nitrate, which are still below the threshold for hygienic water quality standards and drinking water quality standards. . Meanwhile, other water quality parameters, namely levels of Turbidity, Color, Iron, Manganese and Nitrite have levels above the standard threshold for hygienic water quality and drinking water. Therefore, to use well water as for hygienic water that meets the Permenkes No. 492/Menkes/Per/IV/2010 standards, filtration must first be done using a slow sand filter as an alternative to the filter model.

References

Peraturan Menteri Kesehatan Republik Indonesia Nomor 492/Menkes/Per/IV/2010 tentang Pengawasan dan Syarat-syarat Kualitas Air, 2010.

Effendi, H., 2003, Telaah Kualitas Air bagi Pengelolaan Sumber Daya dan Lingkungan Perairan, Kanisius, Yogyakarta.

Hanum, F., 2002, Proses Pengolahan Air Sungai untuk Keperluan Air Minum, Program Studi Teknik Kimia, Fakultas Teknik, Digital Library Universitas Sumatera Utara.

Joko, T., 2010, Unit Air Baku dalam Sistem Penyediaan Air Minum, Graha Ilmu, Yogyakarta.

Said, N.I., 2005. Metoda Penghilangan Zat Besi Dan Mangan Di Dalam Penyediaan Air Minum Domestik, Jurnal Air Indonesia BPPT, Vol. 1 No. 3, 2005.

Vilutama, F.,dkk., 2016, Kadar Fluoride dalam Air Minum Kemasan Tahun 2015, Gema Kesehatan Lingkungan, Vol.14 No, 1, April 2016.

Wiguna, A.A., 2001, Hara Nitrogen Fosfor dan Kalium Drainase Peran pada Beberapa Aliran Sungai di Bali, Laporan Penelitian Kerjasama WWF Indonesia Wallacea Program dan The University of Arizona USA.

Ambarsari, H., 2004, Manajemen dan Teknologi Proses yang Tepat Guna untuk Mengatasi Polusi Nitrat di Lingkungan Tanah dan Air dalam Rangka Pembangunan Berkelanjutan, Prosiding Seminar Pengelolaan Limbah, Balai Lingkungan Teknologi-BPP, Serpong.

Habibah, N., dkk., 2018, Analisis Kuantitatif Kadar Nitrit dalam Produk Daging Olahan di Wilayah Denpasar Dengan Metode Griess Secara Spektrofotometri, International Journal of Natural Sciences and Engineering, Volume 2, Number 1, pp. 1-9.

Mayasari, 2014, Analisis Kualitas Air Hujan Dan Limpasan Melalui Media Green Roof di Kampus IPB Darmaga Bogor, Skripsi.https://repository.ipb.ac.id.

Koper., T. M. Marc, Rosca, Victor, M. Duca dan T. Matheus. D. Groot. , 2009, Nitrogen Cycle Electrocatalysis, Chem. Rev., 109, 2209-2244. https://www.ncbi.nlm.nih.gov.

Downloads

Published

2020-10-25

Issue

Section

Articles